Designed, built, and serviced in Sullivan, Ohio since 1985
Green Machine portable sump cleaner19 CFM · shop air, no motor50–200µ · bag filtration during intake55–70 GPM · vacuum rate
Application · Batch coolant recycling

Batch coolant recycling
without central
piping.

A portable sump cleaner transfers dirty coolant from individual machine sumps to C.R.O.S.S. Clean coolant remains available for immediate use 24/7/365.

up to85%
reduction in new fluid purchases
up to90%
reduction in waste disposal
Approx. 15 min
typical sump cleaning · compared with about 4 hours manually
No trenching
no central coolant piping required
Batch configuration

Batch recycling does not require central coolant piping

One C.R.O.S.S. can serve multiple machine sumps without a central piping installation. A portable transfer unit collects dirty coolant and delivers it to the system. Clean coolant is drawn from the system as needed.

Portable dirty-coolant collectionThe Green Machine or another compatible unit collects coolant along with swarf, chips, and sludge, then transfers the coolant to the system.
Clean-coolant distribution can be addedThe optional Coolant Return System pumps clean coolant through facility piping for distribution across the shop.
Recycling performance is retainedBoth transfer methods support up to 85% lower new-fluid purchases and up to 90% lower disposal costs.
Review central coolant filtration systems
C.R.O.S.S. coolant recycling system
C.R.O.S.S.
COOLANT RECYCLING · 2–25 GPM
Configuration fit

When batch recycling fits the facility

Batch recycling provides central coolant recovery without installing piping to every machine. Facility layout, machine count, and coolant volume determine the appropriate configuration.

Batch fits when
01Leased facilities or sites where floor modification is not practical
02Machine locations make facility-wide coolant piping impractical
03Portable transfer avoids the cost and disruption of facility-wide coolant piping
04Coolant recycling is needed before clean-coolant piping is scheduledThe optional CRS supports future clean-coolant distribution.
Consider another configuration when
05Facility piping can distribute clean coolant without portable transferCentral configuration
06Central distribution serves the main production cells, while portable transfer serves remote machinesHybrid deployment
07The immediate priority is faster sump cleaning rather than coolant recyclingSump cleaning
08Smaller operations where individual-reservoir equipment better matches the service requirementT.O.S.S. at the sump
Operating consideration

Batch recycling uses scheduled portable coolant transfer. An operator moves the transfer unit between machine sumps and C.R.O.S.S. This avoids a facility piping project while combining coolant transfer with sump-cleaning work already required by the shop.

Batch recycling equipment

Portable transfer and central coolant recycling

A portable transfer unit collects dirty coolant from the machine sumps. C.R.O.S.S. separates contaminants, stores clean coolant, and prepares it for reuse.

55–70 GPMGreen Machine portable sump cleaner19 CFM AIRGreen Machine
Dirty-coolant collection

Portable coolant collection and transfer

Green Machine · air-powered portable sump cleaner

Vacuum collection removes coolant, chips, and sludge from the sump. Bag filtration captures solids during transfer, and the unit discharges directly to C.R.O.S.S. A typical sump cleaning that can require about four labor-hours can be completed by one person in approximately 15 minutes.

Vacuum rate55–70 GPM, air-powered on 19 CFM of shop air, no electric motor
Filtration50-to-200-micron bag captures swarf and chips before the fluid reaches the dirty tank
DTS optionA second tank carries clean coolant, allowing dirty-coolant removal and clean-coolant refill during the same sump service cycle
View the Green Machine
2–25 GPMC.R.O.S.S. system in batch configuration99.75% REMOVEDC.R.O.S.S.
Separation

Coolant separation, storage, and concentration control

Coolant Recovery Oil Separation System · batch configuration

Dirty tank, oil/water separator, clean tank, and coolant proportioner on one self-contained skid. Dirty coolant enters through the dirty-tank inlet coupling. Potential reclamation or reuse of separated oil depends on its composition, waste classification, and recipient requirements.

Throughput120–1,500 GPH across six models, sized to weekly coolant volume
Separation99.75% of tramp oil and particulate removed, by volume
UtilitiesRequires the specified electrical service and city-water connection, with no central piping installation
View C.R.O.S.S. specs
Compatible transfer equipment

Compatible transfer equipment can also be used. The Green Machine is the recommended EdjeTech sump cleaner, but another compatible vacuum, transfer tote, or pumping unit can feed the C.R.O.S.S. dirty-tank inlet.

Confirm fit with an engineer
Batch recycling workflow

Planned service across multiple machine sumps

Green Machine portable sump cleanerPortable collection
Green Machine equipment view. This unit collects and transfers coolant during scheduled sump service.
Complete C.R.O.S.S. coolant recycling systemRecycling station
C.R.O.S.S. equipment view. Delivered coolant is processed at the recycling station.
01

Vacuum the sump

The transfer unit collects coolant along with chips, sludge, and tramp oil. A typical sump cleaning takes approximately 15 minutes.

02

Transfer coolant to C.R.O.S.S.

The portable transfer unit moves to C.R.O.S.S. and discharges into the dirty tank through the inlet coupling.

03

C.R.O.S.S. removes contaminants

The system processes dirty coolant while maintaining clean coolant for immediate use 24/7/365.

04

Return clean coolant

Refill from the clean-coolant outlet. A Green Machine with the DTS configuration can return clean coolant on the same sump visit.

Each sump is serviced according to a planned schedule. The system recovers coolant for reuse, reducing new-fluid purchases and disposal volume.

Batch recycling performance

Recovery performance without central piping

Portable transfer changes how coolant moves through the facility, not how C.R.O.S.S. separates contaminants and prepares coolant for reuse.

New-fluid purchases
up to85%
Reduction in new coolant purchases, year over year
Disposal
up to90%
Reduction in waste sent to the hauler
Labor · batch configuration
Approx. 15 min
Typical sump cleaning with the Green Machine, compared with about 4 hours manually
Coolant transfer · batch configuration
No trenching
Portable transfer avoids central coolant piping and floor trenching
Facility requirements

Floor space, utilities, and a transfer schedule

Footprint
60 × 42 inThe smallest 250 model (2 GPM). Footprint scales with the model line.
Electrical & water
Single or three phaseSingle-phase on the 250 and 450, three-phase on the 850 and up, plus city water for the proportioner.
Shop air
19 CFMThe Green Machine requires 19 CFM of shop air and adequate aisle clearance. Its narrow profile supports movement between machines.
Transfer schedule
Planned sump serviceService frequency is based on sump count, coolant volume, and operating conditions.
Configuration questions

Planning a batch recycling system

  • 01

    Is the Green Machine required for batch recycling?

    No. Any compatible sump cleaner or pumping unit can feed the system. The Green Machine is the recommended EdjeTech unit because it filters coolant during intake, and the DTS configuration can refill the sump during the same service cycle.

    See the Green Machine
  • 02

    Can clean-coolant distribution be added later?

    The Coolant Return System is available within the same model line for clean-coolant distribution. A hybrid configuration can serve the main production cells through piping while portable equipment serves remote machines. If future expansion is planned, EdjeTech can confirm whether the selected unit can accept the Coolant Return System later.

    Hybrid deployment
  • 03

    How many machines can one batch setup cover?

    Machine count alone does not determine capacity. Total coolant volume, required processing rate, sump-service frequency, and the model line's 120 to 1,500 GPH range determine how many machines one system can support. For smaller operations, EdjeTech may recommend individual-reservoir equipment instead.

    Estimate potential savings